FAP
230N-1L
Description
On receiving a fire signal from a fire detector
or a manual alarm box, the FAP 230N-1 L conventional
fire alarm panel gives a visual alarm, as well
as an audible alarm, to alert the alarm panel
operator. It also produces alarms to alert the
occupants of the building premises.
|
Feature
- Conventional
type
- Alarm
Verification type (Alarm Verification time
: 60seconds)
- Various
test functions : fire indication test. auxiliary
power supply test and alarm verification time
test.
- Durable
LED indications
- Back-up
power supply (Ni-Cd battery, 24VDC)
- Easy
maintenance
- Automatic
self-checking system
|
|
|
FAP
28E-5L
Description
On receiving a fire signal from a fire detector
or a manual
alarm box, the FAR 28E-5L conventional fire alarm
panel
gives a visual alarms indicating the alarm point,
as well as an audible alarm, to alert the alarm
panel operator. It also produces alarms to alert
the occupants of the building premises.
The FAP 28E-5L conventional fire alarm panel has
indication of the alarm points by individual zone
lamps.
|
|
Feature
:
- Conventional
type
- Alarm
Verification type (Alarm verification time :
60seconds)
- The
alarm verification function can be released
with respect to each individual line.
- Various
test functions : fire indication 'test, line
continuity
test, auxiliary power supply test and alarm
verification time test.
- Durable
LED indications
- Back-up
power supply (Ni-Cd battery, 24VDC)
- Easy
maintenance
- Automatic
self-checking system
|
|
|
Description
The FAP129N series fire alarm panel was developed
to provide a cost- and space-saving conventional
fire alarm panel together with more user-oriented
functions. The size of the panel is approximately
one-half the depth. one-half the area, one-fourth
the volume, and one-fifth the weight of our
last 20-zone fire alarm panel. The cabinet
is made of ABS resin with non-flammability
to UL-94V2.
|
|
Feature
:
- Save-cost
and save-space
- Available
for 10 and 20 fire alarm zones
- Conventional
type
- Alarm
verification type
- Name
plate and a digital display for alarmed
zones
- Programmable
output signal
- NLCd
stand-by battery built in
- Handset
built in for maintenance
- Programmable
function at site
- Automatic
self-checking
- Various
test facilities for maintenance
- Surge
arrester built in for power lines
|
|
|
Description
The FAP128N series fire alarm panel was
developed to provide a cost- and space-saving
conventional fire alarm panel together with
more user-oriented functions.
The height of the panel comes to approximately
80% of that of our last 40-zone fire alarm
panel. The weight of the panel is reduced
by approximately 70% of that of our last
40-zone fire alarm panel.
The cabinet is made with steel sheet having
a depth of 1.2 mm (Door panel) and 1.6 mm
(Cabinet).
|
|
Feature
:
- Save-cost
and save-space
- Available
for 30. 40 and 50 fire alarm zones
- Conventional
type
- Alarm
verification type
- Name
plate and a digital display for alarmed
zones
- Programmable
output signal
- Ni
Cd stand-by battery built in
- Handset
built in for maintenance
- Programmable
function at site
- Automatic
self-checking
- Various
test facilities for maintenance
- Surge
arrester built in for power lines
|
|
|
Description
The FDP series rate-of-rise detectors operate
on the pneumatic principle. i.e. the expansion
of heated air in the air chamber, and respond
to rapid rise in temperature caused by fire.
A slow or gradual temperature rise as would
result from a heating system in the building
does not activate the detector because any
moderate excess air is released into the
atmosphere through the air vent. By the
use of a common base, the FDP series rate-of-rise
detectors are interchangeable with NOHMI
smoke detectors (FDS series and FDK series).
The detector is equipped with a
response indicator by which it is possible
to readily identify the alarming detector.
This feature facilitates the functional
check of the detector.
|
Feature
:
- Conventional
type
- Simple
mounting
- 2-wire
system
- Easy
maintenance
- Alarm
response lamp (LED)
- Low
profile
- Approved
by Japan Fire Equipment Inspection Institute
|
|
|
|
Description
The FDL series fixed temperature detectors
use bi-metal snap discs as heat sensing
elements, which close the alarm contacts
when ambient temperature has reached a predetermined
level of temperature. The detectors are
automatically self-restoring after operation,
when the ambient temperature falls below
the operating temperature.
This
series also includes water-proof types,
which are suitable for use in highly humid
environments such as a kitchen, a bathing
room, a drying room.
The anti-corrosive fixed temperature detector
has a heat sensor and a heat receiving plate
coated with an anti-corrosive agent to be
used in a space where the detector is subject
to corrosive gases against copper or alrninum.
This type of fixed temperature detector
is used, for instance, in a storehouse where
filled with a fumigation gas as an insecticide
for goods inside.
|
Feature
:
- Equipped
with a L. E. D. to indicate signal initiation
- Can
be tested to make sure of readiness to
alarm
- Conventional
type
- wire
system
- Water-proof
type available
- Acid-proof
type available
- Anti-corrosive
type available
- Approved
by Japan Fire Equipment Inspection Institute
|
|
|
Description
The
FDK series photoelectric smoke detectors
detect combustion products (smoke) generated
by fire, and transmit an alarm signal to
the fire control panel. The photoelectric
smoke detector can detect a fire in an earlier
stage than a heat detector. Generally, this
detector is installed in the spaces such
as the basements, ordinary floors, corridors,
staircases, elevator shafts, etc.
|
Feature
:
- Small
monitoring current of 45 uA
- 2-wire
systemAlarm response lamp (LED)
- Simple
mounting
- Very
easy maintenance
- Low
profile
|
|
|
Description
The NOHMI'S FMM series manual fire alarm
box is used to manually initiate a fire
alarm signal by pushing the plexi-glass
which is connected to the
push - button switch. The operated plexi
- glass is restored by only lifting up the
reset lever inside the jack cover.
telephone
jack is provided inside the jack cover on
FMM120A and FMM160A. Putting the plug of
a handset into the jack makes the tele-communication
be ready between the fire alarm control
panel and the manual fire alarm box.
A
response lamp is also provided on FMM120A
and FMM160A to indicate that a fire alarm
signal has been received at the fire alarm
control panel.a response indicator by which
it is possible to readily identify the alarming
detector. This feature facilitates the functional
check of the detector.
|
|
Feature
:
- Push-button
type manual fire alarm box
- Restorable
plexi-glass used
- Easy
reset after operation
- Tele-communication
means provided (FMM120A and FMM160A only)
- Response
lamp provided (FMM120A and FMM160A only)
' '
- Compatible
with conventional fire alarm control panels
only
- Able
to start the hydrant pump with NOHMI's
fire alarm panel and NOHMI'S hydrant pump
starting relay box
- Approved
by Japan Fire Equipment Inspection Institute
|
|
|
Description
The NOHMI'S fire alarm bell provides a higher
level
of sound with a high efficiency and a lower
level of
RFI noise.
It
is recommended that fire alarm bells are
installed so that the sound level at any
place is higher than 65
dB or higher than 6 dB plus the ambient
sound level.
|
Feature
:
- Motor
driven type alarm bell
- High
sound output with low current consumption
- Hiigh
durability
- Low
RFI noise
- With
Line Fault Detection Function (FBM 023Z-D)
- Drip-proof
type available
- Lead
wire connection
- Approved
by Japan Fire Equipment Inspection Institute
|
|
|
|
|
|
©
Copyright 2005. Prokornassociate Co.,Ltd. All rights reserved.
|
|
|