Testing EquipmentsFire Protection ProductsSafty ProductsExit LightSecurtiy Products
  GIS ProductsLaw Enforcement Products

 

 
Fire Alarm Panel
 

FAP 230N-1L

Description
On receiving a fire signal from a fire detector or a manual alarm box, the FAP 230N-1 L conventional fire alarm panel gives a visual alarm, as well as an audible alarm, to alert the alarm panel operator. It also produces alarms to alert the occupants of the building premises.

 

Feature

  • Conventional type
  • Alarm Verification type (Alarm Verification time : 60seconds)
  • Various test functions : fire indication test. auxiliary power supply test and alarm verification time test.
  • Durable LED indications
  • Back-up power supply (Ni-Cd battery, 24VDC)
  • Easy maintenance
  • Automatic self-checking system
FAP 28E-5L

FAP 28E-5L

Description
On receiving a fire signal from a fire detector or a manual
alarm box, the FAR 28E-5L conventional fire alarm panel
gives a visual alarms indicating the alarm point, as well as an audible alarm, to alert the alarm panel operator. It also produces alarms to alert the occupants of the building premises.
The FAP 28E-5L conventional fire alarm panel has indication of the alarm points by individual zone lamps.

 

Feature :

  • Conventional type
  • Alarm Verification type (Alarm verification time : 60seconds)
  • The alarm verification function can be released with respect to each individual line.
  • Various test functions : fire indication 'test, line continuity
    test, auxiliary power supply test and alarm verification time test.
  • Durable LED indications
  • Back-up power supply (Ni-Cd battery, 24VDC)
  • Easy maintenance
  • Automatic self-checking system
FAP 129N Series
Description
The FAP129N series fire alarm panel was developed to provide a cost- and space-saving conventional fire alarm panel together with more user-oriented functions. The size of the panel is approximately one-half the depth. one-half the area, one-fourth the volume, and one-fifth the weight of our last 20-zone fire alarm panel. The cabinet is made of ABS resin with non-flammability to UL-94V2.

 

Feature :

  • Save-cost and save-space
  • Available for 10 and 20 fire alarm zones
  • Conventional type
  • Alarm verification type
  • Name plate and a digital display for alarmed zones
  • Programmable output signal
  • NLCd stand-by battery built in
  • Handset built in for maintenance
  • Programmable function at site
  • Automatic self-checking
  • Various test facilities for maintenance
  • Surge arrester built in for power lines
FAP 128N Series

Description
The FAP128N series fire alarm panel was developed to provide a cost- and space-saving conventional fire alarm panel together with more user-oriented functions.
The height of the panel comes to approximately 80% of that of our last 40-zone fire alarm panel. The weight of the panel is reduced by approximately 70% of that of our last 40-zone fire alarm panel.
The cabinet is made with steel sheet having a depth of 1.2 mm (Door panel) and 1.6 mm (Cabinet).

 

Feature :

  • Save-cost and save-space
  • Available for 30. 40 and 50 fire alarm zones
  • Conventional type
  • Alarm verification type
  • Name plate and a digital display for alarmed zones
  • Programmable output signal
  • Ni Cd stand-by battery built in
  • Handset built in for maintenance
  • Programmable function at site
  • Automatic self-checking
  • Various test facilities for maintenance
  • Surge arrester built in for power lines
FDP SERIES

Description
The FDP series rate-of-rise detectors operate on the pneumatic principle. i.e. the expansion of heated air in the air chamber, and respond to rapid rise in temperature caused by fire. A slow or gradual temperature rise as would result from a heating system in the building does not activate the detector because any moderate excess air is released into the atmosphere through the air vent. By the use of a common base, the FDP series rate-of-rise detectors are interchangeable with NOHMI smoke detectors (FDS series and FDK series). The detector is equipped with
a response indicator by which it is possible to readily identify the alarming detector. This feature facilitates the functional check of the detector.

Feature :
  • Conventional type
  • Simple mounting
  • 2-wire system
  • Easy maintenance
  • Alarm response lamp (LED)
  • Low profile
  • Approved by Japan Fire Equipment Inspection Institute
FDL SERIES

Description
The FDL series fixed temperature detectors use bi-metal snap discs as heat sensing elements, which close the alarm contacts when ambient temperature has reached a predetermined level of temperature. The detectors are automatically self-restoring after operation, when the ambient temperature falls below the operating temperature.

This series also includes water-proof types, which are suitable for use in highly humid environments such as a kitchen, a bathing room, a drying room.
The anti-corrosive fixed temperature detector has a heat sensor and a heat receiving plate coated with an anti-corrosive agent to be used in a space where the detector is subject to corrosive gases against copper or alrninum. This type of fixed temperature detector is used, for instance, in a storehouse where filled with a fumigation gas as an insecticide for goods inside.

Feature :
  • Equipped with a L. E. D. to indicate signal initiation
  • Can be tested to make sure of readiness to alarm
  • Conventional type
  • wire system
  • Water-proof type available
  • Acid-proof type available
  • Anti-corrosive type available
  • Approved by Japan Fire Equipment Inspection Institute
FDK SERIES

Description
The FDK series photoelectric smoke detectors detect combustion products (smoke) generated by fire, and transmit an alarm signal to the fire control panel. The photoelectric smoke detector can detect a fire in an earlier stage than a heat detector. Generally, this detector is installed in the spaces such as the basements, ordinary floors, corridors, staircases, elevator shafts, etc.

Feature :
  • Small monitoring current of 45 uA
  • 2-wire systemAlarm response lamp (LED)
  • Simple mounting
  • Very easy maintenance
  • Low profile
FMM SERIES

Description
The NOHMI'S FMM series manual fire alarm box is used to manually initiate a fire alarm signal by pushing the plexi-glass which is connected to the
push - button switch. The operated plexi - glass is restored by only lifting up the reset lever inside the jack cover.

telephone jack is provided inside the jack cover on FMM120A and FMM160A. Putting the plug of a handset into the jack makes the tele-communication be ready between the fire alarm control panel and the manual fire alarm box.

A response lamp is also provided on FMM120A and FMM160A to indicate that a fire alarm signal has been received at the fire alarm control panel.a response indicator by which it is possible to readily identify the alarming detector. This feature facilitates the functional check of the detector.

Feature :

  • Push-button type manual fire alarm box
  • Restorable plexi-glass used
  • Easy reset after operation
  • Tele-communication means provided (FMM120A and FMM160A only)
  • Response lamp provided (FMM120A and FMM160A only) ' '
  • Compatible with conventional fire alarm control panels only
  • Able to start the hydrant pump with NOHMI's fire alarm panel and NOHMI'S hydrant pump starting relay box
  • Approved by Japan Fire Equipment Inspection Institute
FBM023Z-D/FBD011

Description
The NOHMI'S fire alarm bell provides a higher level
of sound with a high efficiency and a lower level of
RFI noise.

It is recommended that fire alarm bells are installed so that the sound level at any place is higher than 65
dB or higher than 6 dB plus the ambient sound level.

Feature :
  • Motor driven type alarm bell
  • High sound output with low current consumption
  • Hiigh durability
  • Low RFI noise
  • With Line Fault Detection Function (FBM 023Z-D)
  • Drip-proof type available
  • Lead wire connection
  • Approved by Japan Fire Equipment Inspection Institute